Radimage is an ISO 9001-2015 certified company and operates an AERB Authorized and NABL Accredited Laboratory (Certificate Nos: CC-1027 and CC-4685).The facility is traceable to national and international standards. Calibration is performed using certified reference sources, under controlled conditions as per ISO/IEC 17025 norms.
Radimage has calibrated over 19,000 radiation monitoring instruments worldwide since 2014.
Yes, Radimage operates in compliance with ISO/IEC 17025:2017.
In compliance with AERB guidelines, calibration certificates are valid for 2 years for Radiation Monitoring Instruments (RMIs) and Dose Calibrators. SSD teletherapy chambers and Brachy Well chambers calibration certificates are valid for 3 years.
Radimage operates two units: Unit I is located at G-236, Sector-63, Noida for RMIs and Dose Calibrators Unit II is at 503, Ecotech-III, Udyog Kendra-II, Greater Noida for Teletherapy and Brachy Chambers.
Yes, Radimage is both AERB and BARC approved, in addition to being NABL accredited.
Orders must be confirmed via email or courier along with full advance payment, after obtaining the quotation.
Payment should be made through Online, RTGS or Demand Draft (DD) in favor of Radimage Healthcare India Pvt. Ltd.
Quotations are valid for 60 days from the date of issue.
You must share the instrument’s make, model, serial number, operating voltage, shipping address, mode of transport, institute name & GST number, along with any special instructions. Fill the respective calibration form and send it to us for priority appointment.
Yes, GST is applicable @ 18% or as per current regulations prevailing at the time of actual calibration.
Yes, nationwide pickup and drop is possible through reputed courier service at extra charge. Same-day calibration options are available. Please contact lab.
Instruments that fail calibration still incur full charges because the calibration process was fully performed. No disputes accepted at a later date.
If an instrument fails and is repaired and resubmitted within 3 months, the re-calibration is free of cost.
Repair services are offered only upon customer consent and the availability of required components. However, repair timelines are not guaranteed.
Yes, instruments used for both parameters require separate calibration and are charged as two calibrations.
Calibration is performed as per AERB guidelines with a ±15% tolerance.
The certificate includes the instrument details, measured values, operating conditions, percentage deviation, calibration factors and an official pass/fail status.
No. While Radimage can facilitate calibration for items like gas detectors or thermometers through partnered labs on request, they are not legally responsible for the results from these third-party facilities.
Packing at the customer's end is their sole responsibility, and Radimage will use that same packaging for the return of the instrument.
Instruments should be wrapped in bubble/foam sheets, detectors packed separately, and display panels protected with thick thermocol. All inner sides of the box should be lined with foam/EPs.
For logistics-related queries, you may contact Mr. Hari Ram at +91 9811633767 | Tel.: 0120-4263270
Yes, pickup via courier is available on request, though customers are advised to arrange their own logistics for urgent needs.
Courier charges to and from Radimage are to be borne by the customer.
The default insurance cover is ₹5,000. Extra insurance is available @ 4% of the declared value of the instrument.
Radimage is not liable for damage during transit. If an instrument is non-functional upon delivery, Radimage can retest it, but shipping costs must be paid by the customer.
a. Radiation Monitoring Instruments and Dose Calibrators should be sent to: Radimage Healthcare India Pvt. Ltd., G-236, Sector-63, Noida – 201303, U.P. | Tel.: 0120-4263270
b. Teletherapy Chambers and Brachy Well type Chambers should be sent to: Radimage Healthcare India Pvt. Ltd., 503, Udyog Kendra II, Ecotech 3, Greater Noida - 201306 | Tel.: 0120-4112417
If you are couriering a Dose Calibrator, you must use only original OEM packaging to ensure its safety.
If shipping multiple instruments in one box, you must use cushioning between them to prevent contact and damage during transit.
Yes, for same-day calibration, you may send the instrument with your representative, provided a prior appointment has been scheduled.
Please include the Instruction Manual, the last Calibration Certificate, and all essential accessories like electrical, connecting cables and external detectors.
You must send the external detector, detector cable, and power cable. The chamber and monitor must be packed separately.
No, do not send syringe dippers as they are brittle. Radimage maintains spares in the lab.
On request, Radimage can facilitate calibration for items like thermometers, barometers, gas detectors, and densitometers through partnered NABL authorised labs.
Radimage is not responsible for storage or upkeep of instruments if they are left for more than 15 days post-calibration.
You must ensure the instrument is in working condition before dispatch; if it is not, you are required to inform Radimage beforehand.
Yes, all data shared by customers is kept strictly confidential.