Allinone - mini

miniAllinOne is a unique compact synthesizer dedicated to the preparaon of diagnosc and therapeuc radiotracers. You can use this synthesizer for the producon of radiotracers labelled with 68Ga, 177Lu, 99mTc, 89Zr, 64Cu, 90Y, 188Re, 203Pb among others, all on the same instrument to meet the evolving needs of the nuclear medicine department.

The synthesizer for diagnosc and therapeuc radiotracers • Small footprint
• Full automaon
• Matches with all generators
• Labelling of radiometals
• As easy to use as a coffee machine



Allinone - mini

Main Tracers

Allinone - mini

Routine Production

miniAllinOne is the best choice for easy and reliable roune delivery of radiopharmaceucals thanks mainly to:
• Full automaon
• Processes compable with all 68Ga generators
• Ready for use consumables
• Proven usage with 68Ga, 177Lu, 18F
This plaorm allows radiotracers labelled with 18F, 68Ga, 177Lu, 99mTc, 89Zr, 64Cu, 90Y, 188Re, 203Pb to all be prepared with the same instrument. A range of dedicated table­top and wheel­mounted compact hot cells ensures a perfect protecon and ergonomic working condion





Routine Production

Cassees and reagents for each tracer are available for miniAIO. The comprehensive reagent kits avoid the need of sourcing consumables from several suppliers. Cassees are GMP manufactured and are provided in individually sealed pouches, fully assembled and ready to use. The RFID chip scanner system avoid manual transcripon mistakes and warrants operators to work with the right reagents kits. Subsequent cassee rinsing eliminates most of the residual acvity allowing a quick replacement for any upcoming producon.



Allinone - mini
Allinone - mini

Installed at:

• Amrita Hospital, Kochi
• Max Hospital, New Delhi
• Ruby Hall Clinic, Pune
• Ambani Hospital, Mumbai

Allinone - mini

Installed at:

• Yashoda Hospital, Hyderabad • B.L. Kapoor, New Delhi
• DIFI, Delhi
• Artemis Healthcare, Delhi
• Medanta Healthcare, Delhi
• Jaslok Hospital, Mumbai
• Mahavir Cancer Sansthan, Jaipur
• Quadra Hospital, Kolkata
• INMAS, Delhi (under installaon)



Allinone - mini

miniAllinOne is also a avery effecve radiochemistry development tool. Its unsurpassed versality allows researchers to easily address emerging diagnosc and therapeuc procedures, exemplified by the increasing interest in theranosc.
Innvave processes with 18F, 68Ga, 177Lu, 99mTc, 89Zr, 64Cu, 90Y, 188Re, 203Pb as well as with other tracers have been quickly implemented.


Software

miniAllinOne includes a user­friendly graphical interface with flexible research­oriented features. It makes it easy for radio­chemists to design their own fluid pathway layout, program their processes graphically and even share their developments with other groups.

The soware accurately records all parameters, which allows the process sequences to be fully analyzed and opmized. Data of each run is stored in a library making it even possible to replay any previous run in full detail.

The miniAllinOne soware can be operated from anywhere on the LAN with customizable user­access rights.


Other Services

Trasis also offers custom services for the miniAllinOne.

Specific procedures and on­demand synthesis process developments can be implemented on the miniAllinOne for a very large range of applicaons. Trasis also designs and produces customized cassees and dedicated reagents kits.


Related Products

Allinone - mini

Specifications

Allinone - mini

A widely recognized online service

An online service team combining IT, mechanical and chemistry skills, will provide you with an outstanding service experience. Well over 90% of the quesons can be answered remotely. Personalized training opons allow to wisely use the advanced hardware and soware features. These sessions can be performed on site, in our facilies or remotely.


Allinone - mini

UniDose - The Hospital Dispenser

Fully automac dispensing system for any PET radiopharmaceucals
• Fast setup
• Drasc exposure reducon
• Traceability
• Safe use in hospitals

UniDose, housed in a hotcell, is an automated dispenser dedicated to fragment radiotracers bulk vials into paent dose units. It addresses the needs of nuclear medicine departments in hospitals wishing to automaze the gragmentaon from vialcondioned radiotracers into paent doses units. Over and above a higher radio­protecon, this system allows an access to a broad range of preparaons, a full compliance with pharmaceucal regulaons, a proven reliability together with decreased operaonal costs. It also offers especially flexible and safe injecon condions in nuclear medicine facilies.
With Unidose you are sure to fulfill all the dispensing and injecon needs in your nuclear medicine department. Along with the automac filling machine, a wide range of accessories will help you cover all aspects related to dose preparaon up to paent injecon:
• Ergonomic hot cell
• Ready­to­use consumables
• Dose tungsten shield
• Moblie radiaon protecon screen


QuickFill-The Pharmacy Dispenser

QuickFill is an automated dispenser housed in a hotcell and dedicated to prepare batches of PET and SPECT paent doses for distribuon from radiopharmacies. With Quickfill, the radiopharmacists can rely on a robust and fast tool to ensure quality preparaons at the lowest cost. In the daily pracce, QuickFill leads to a considerable reducon of the shipment containers weight and offers a parcularly comfortable soluon for secure and easy injecons.


Allinone - mini

Allinone - mini

Dose Administration

Simplify the administraon of SPECT and PET radiopharmaceucals and reduce your exposure!

The Injecon Set protects the medical staff and allows the complete transfer of the acvity to the paent